Dell EMC Best Practices
Best Practices for Securing Dell EMC SC Series
Storage
Abstract
This paper explores the technologies available for building a secure Dell
EMC™ SC Series storage area network (SAN) with operational
environment best practices and self-encrypting drives.

October 2018
Revisions
2 Best Practices for Securing Dell EMC SC Series Storage | BP1082
Revisions
Date Description
June 2014 Initial release
April 2015 Minor updates
April 2016 Updates for SCOS7.0 and DSM 2016 R1
October 2018 Validated for SCOS 7.3 and DSM 2018; added CloudIQ and air-gapped sections

Acknowledgements
Updated by: David Glynn

The information in this publication is provided “as is.” Dell Inc. makes no representations or warranties of any kind with respect to the information in this
publication, and specifically disclaims implied warranties of merchantability or fitness for a particular purpose.

Use, copying, and distribution of any software described in this publication requires an applicable software license.

© 2014–2018 Dell Inc. or its subsidiaries. All Rights Reserved. Dell, EMC, Dell EMC and other trademarks are trademarks of Dell Inc. or its subsidiaries.
Other trademarks may be trademarks of their respective owners. Published in the USA. [10/11/2018] [Best Practices] [BP1082]

Dell believes the information in this document is accurate as of its publication date. The information is subject to change without notice.
Additional resources
3 Best Practices for Securing Dell EMC SC Series Storage | BP1082
Table of contents
Revisions……………………………………………………………………………………………………………………………………………………….. 2
Acknowledgements …………………………………………………………………………………………………………………………………………. 2
1 Introduction ………………………………………………………………………………………………………………………………………………. 4
1.1 Audience …………………………………………………………………………………………………………………………………………. 4
2 SC Series SAN …………………………………………………………………………………………………………………………………………. 5
2.1 Basic security features ……………………………………………………………………………………………………………………… 6
2.2 Operational environment …………………………………………………………………………………………………………………… 7
2.3 Administrative access points ……………………………………………………………………………………………………………… 7
2.4 SupportAssist and Secure Console …………………………………………………………………………………………………….. 8
2.5 SupportAssist at air-gapped sites ……………………………………………………………………………………………………….. 8
2.6 CloudIQ data sources ……………………………………………………………………………………………………………………….. 8
3 Protect data at rest with self-encrypting drives ……………………………………………………………………………………………… 9
4 Protect data in flight …………………………………………………………………………………………………………………………………. 10
5 Security scanning ……………………………………………………………………………………………………………………………………. 11
5.1 SCOS port list ………………………………………………………………………………………………………………………………… 11
5.2 DSM port list ………………………………………………………………………………………………………………………………….. 12
5.3 DSM client port list ………………………………………………………………………………………………………………………….. 14
5.4 DSM Server Agent port list ………………………………………………………………………………………………………………. 14
6 Conclusion ……………………………………………………………………………………………………………………………………………… 15
A Additional resources ………………………………………………………………………………………………………………………………… 16
A.1 Related resources ………………………………………………………………………………………………………………………….. 16

Additional resources
4 Best Practices for Securing Dell EMC SC Series Storage | BP1082
1 Introduction
Data security is a primary concern in any IT environment. Business-critical or confidential information must be
protected from unauthorized access and properly disposed of when required. Many organizations are
compelled to implement data-protection technologies due to regulatory compliance.
This document provides best practices for deploying a secure Dell EMC™ SC Series SAN to prevent
unauthorized access to administrative interfaces and to protect data at rest using self-encrypting drives.
1.1 Audience
This paper is intended for storage administrators, SAN system designers, storage consultants, network and
security consultants, or anyone tasked with building a secure, production SAN using SC Series storage. It is
assumed that all readers have experience in designing or administering a shared storage solution. Also, there
are some assumptions made in terms of familiarity with all current Ethernet standards as defined by the
Institute of Electrical and Electronic Engineers (IEEE) as well as TCP/IP and iSCSI standards as defined by
the Internet Engineering Task Force (IETF). Additional resources
5 Best Practices for Securing Dell EMC SC Series Storage | BP1082
2 SC Series SAN
The SC Series includes high performance, enterprise-level SAN devices that support Fibre Channel (FC),
Fibre Channel over Ethernet (FCoE), and iSCSI connections. They provide fast, network-based storage to
servers.
An SC Series SAN consists of at least one controller and disk enclosure interconnected with SAS, or Fibre
Channel in some legacy SC Series systems. For more advanced storage-administration capabilities, the Dell
Storage Manager (DSM), formerly Enterprise Manager, application may be used to administer multiple SC
Series SANs. DSM and the associated Data Collector service run on a separate server on the same
management network as the SC Series storage. Storage administrators use this management network to
access and administer DSM and each SC Series system.
In addition to the management network, each SC Series array is connected to a SAN consisting of the SC
Series front-end adapters and the FC, FCoE, or iSCSI initiators of the host servers.

Functional block diagram of the SC Series SAN components
Additional resources
6 Best Practices for Securing Dell EMC SC Series Storage | BP1082
2.1 Basic security features
An SC Series SAN offers a variety of mechanisms for preventing unauthorized access to administrative
access points or to storage volumes. In addition, self-encrypting drives (SEDs) are available to provide
security for data at rest.
Note: Common Criteria (CC) for IT Security Evaluation certification of SC Series storage is in process at the
time of this publication (certificate number: BSI-DSZ-CC-0847):
https://www.bsi.bund.de/EN/Topics/Certification/incertification.html
The primary security features of an SC Series SAN include the following:
Event auditing: For administrative events at DSM or Dell™ Storage Center OS (SCOS), this records the
controller, user identity and role, date, time, and outcome.
User identity and authentication: This ensures that users authenticate with proper credentials to access
administrative functions or storage volumes. Management users require a password to authenticate, Fibre
Channel initiators authenticate using their persistent WWN, and iSCSI initiators can be authenticated using
unidirectional or bidirectional CHAP.
Data access control: This prevents unauthorized access to storage volumes by requiring an explicit volume
mapping from each Fibre Channel or iSCSI initiator to each storage volume. By default, the SC Series system
blocks access to all storage volumes, a behavior known as LUN masking. Fibre Channel environments also
implement zoning for additional security.
Residual information protection: Whenever a new volume is created, SCOS does not allow a storage host
to read from unwritten areas on the volume, and newly allocated pages are zeroed before host access.
Security role management and access: This allows users to have different levels of authorization. In
addition to the administrator role for administering DSM and SCOS, there is also a restricted volume manager
role that must be granted permission to volumes, storage hosts, or disk folders. A read-only reporter role can
view all information but cannot make changes.
Reliable time stamps: Using an internal time source or an NTP server, time stamps within auditing and logs
are synchronized.
Trusted channel communication: Management traffic to SCOS and DSM is encrypted using HTTPS over
TCP port 443 and TCP port 3033.
Additional resources
7 Best Practices for Securing Dell EMC SC Series Storage | BP1082
2.2 Operational environment
Physical security is always the most basic form of protection for any business-critical infrastructure. To make
sure an SC Series SAN operates in a physically secure environment that is accessible only to authorized
administrators, use the following best practices:
• Ensure secondary services, such as DNS and NTP, originate from trustworthy sources.
• Physically secure and logically protect the SAN and the management network using firewalling or
network isolation. From a physical security and performance standpoint, SAN traffic should be
physically separate from the end-user application network. However, in environments with shared
networking infrastructure, SCOS supports layer-2 VLAN partitioning to logically separate the iSCSI
and LAN traffic on the same physical hardware. Although the SAN and LAN traffic is separated onto
different VLAN networks, resource contention with shared hardware means that disproportionate LAN
traffic has the potential to negatively affect storage performance.
• Be sure that password complexity is consistent with the authentication policy of the organization. The
administrator must change the default password during initialization of the SC Series system. If the
password is lost, the administrative password can be reset through physical access using a special
procedure only available by contacting Dell Support.
• Apply firmware, security and anti-virus updates regularly to all systems having access to the SAN. In
particular, keep web browsers used for remote administrative access up to date.
2.3 Administrative access points
Each SC Series system can be accessed administratively using either the management Ethernet port, or the
controller serial port. The controller serial port is only to be used under the direction of Dell Support for
advanced troubleshooting and is not intended to be used for daily administrative tasks.
The SC Series array can be configured to allow third-party monitoring tools to access the array controllers
using SNMP. An SC Series system can also be configured to send email alerts to an SMTP server or to send
system events to a syslog server. SNMP access and syslog logging are disabled by default, whereas SMTP
email alerts are set up during initial SC Series configuration or afterwards.
SC Series systems can also be accessed using one of two scripting utilities. Scripts can be created with
Microsoft
®
PowerShell
®
, or the Dell Storage REST API. With these utilities, administrative commands issued
to the array are encrypted over HTTPS and must be authenticated with SCOS credentials.
In addition, there are other software integration components from Dell EMC and from third parties, such as
Dell Foglight for Storage Management, the VMware
®
vRealize
®
Operations™ plug-in, and the CommVault
®

Simpana
®
plug-in, which access SCOS or DSM to provide additional management or reporting capabilities.
For more information, refer to the corresponding software product documentation.
Each SC Series controller also includes an iDRAC out-of-band management controller that can be used for
administrative tasks, such as remotely power cycling the controller chassis. The iDRAC interface is also used
by the SC Series system to apply firmware updates to controller hardware during upgrades. An IP address
should be assigned to the iDRAC to make it accessible using a web browser or the remote CLI utility
RACADM. Since iDRAC functionality is required for upgrades, firewalls should be used to secure the
environment and communications should be limited to only from the SC Series management IP addresses.
Additional resources
8 Best Practices for Securing Dell EMC SC Series Storage | BP1082
2.4 SupportAssist and Secure Console
SC Series includes two features that enhance the enterprise support that Dell provides:
Dell SupportAssist (formerly known as Phone Home) is a service that allows SCOS to automatically send
diagnostic logs and alerts to and download firmware updates from Dell.
Secure Console is a service that allows Dell Support engineers to access the SCOS console using Secure
Shell (SSH).
SupportAssist is enabled by default but can be disabled in the SCOS settings. Secure Console services are
disabled by default. Neither SupportAssist nor Secure Console requires inbound ports to be open at the
network firewall while running. Each service, when enabled, makes an outbound connection to a Dell EMC
internet server when needed. In the case of Secure Console, this outbound connection allows Dell Support
engineers to connect to SCOS using SSH tunneling.
SupportAssist requires outbound TCP port 443 to be open and Secure Console requires outbound TCP port
22 and 8443 to be open.
2.5 SupportAssist at air-gapped sites
There are occasions when configuring the SC Series capabilities for SupportAssist is not an option, such as
an air-gapped site configuration. For such occasions, SupportAssist data can be manually exported from SC
Series storage and sent to Dell Support.
For instruction on how to perform this task, see the Saving SupportAssist Data to a USB Flash Drive Tech
Note available on Dell.com/Support.
2.6 CloudIQ data sources
CloudIQ provides centralized monitoring for numerous Dell EMC products across multiple sites. It enables
proactive serviceability that informs customers about issues before there is impact to their environment. All of
this is provided through a dashboard that aggregates key information such as system health scores,
performance metrics, and current capacity and trends.
CloudIQ leverages the existing SC Series SupportAssist data, so there are no additional ports or protocols
used for transferring the information from the customer site.
Additional resources
9 Best Practices for Securing Dell EMC SC Series Storage | BP1082
3 Protect data at rest with self-encrypting drives
Data at rest is the data that resides on the physical hard drives within the SC Series enclosure. Though
difficult, it is possible that bits of data could be extracted from a conventional hard drive if physical security is
breached and the hard drive is removed from an enclosure.
Self-encrypting drives (SEDs) guard against this threat by encrypting data as it is written to the disk and
decrypting data as it is read. Starting in version 6.5, SCOS implements this technology in a licensed feature
called Secure Data which is transparent to the storage user. Since the encryption is offloaded to the SED,
performance impact is negligible.
The following points provide further information about Secure Data behavior:
• An SED will not encrypt or decrypt data if Secure Data is unlicensed.
• Secure Data requires an external key management server, such as Gemalto™ SafeNet
KeySecure™.
• A secure data folder can only contain disks identified by SCOS as FIPS‐140‐2 certified.
• When an SED is assigned to a secure data folder, the existing media encryption key (MEK) on the
disk is destroyed and a new MEK is created, rendering all previous data unreadable. This process is
known as a cryptographic erase.
• A cryptographic erase is also performed when an SED is removed from a secure data folder. If user
data is present on the SED, SCOS will issue a warning prior to un-assigning the drives and
destroying and recreating the MEK. This cryptographic erase obviates the need for time-consuming
hard-drive data wiping prior to recommissioning.
• When an SED assigned to a secure data folder is physically removed from an enclosure, it locks on
reset and can only be unlocked using authority credentials stored on the key management server.
• An SED will lock on reset after a loss of power to the controller and enclosure simultaneously or in the
event of a controller flash card failure. After the next SCOS boot, the startup wizard will prompt the
administrator to confirm the key management server configuration before unlocking the SED. If a
flash card fails, Dell Support can assist with replacing the flash card and unlocking the SED.
• Replicating a secure data folder to an unsecure folder is permitted, but the data on the drives in the
unsecure folder will not be encrypted.
Note: For more information on the Dell EMC implementation of SED technology, see the Dell Compellent
Storage Center System Manager Administrator’s Guide on the Knowledge Center at the SC Series Customer
Portal, as well as the document, Using Self-Encrypting Drives (SEDs) with Dell EMC SC Series Storage.
Additional resources
10 Best Practices for Securing Dell EMC SC Series Storage | BP1082
4 Protect data in flight
Data in flight is data as it is transmitted over the network within packets. These network packets contain
unencrypted data payloads that can be read if the packet is captured in transit.
SC Series storage relies on the physical security of storage and networking hardware and the logical or
physical isolation of the SAN and management networks from external networks. It does not support IPsec
network-layer security or Fibre Channel encryption.
It is recommended to secure WAN replication traffic with a virtual private network (VPN) using a WAN
optimizer or router.
Additional resources
11 Best Practices for Securing Dell EMC SC Series Storage | BP1082
5 Security scanning
No security analysis would be complete without a review of open IP network protocol ports for a given system.
Nmap, the open source network discovery and security-auditing tool, was used for this purpose. The following
tables list all TCP and UDP ports and services for SCOS and DSM. Not all services are enabled by default.
For each port, the protocol is listed as well as the actual port usage.
In order for SCOS and its associated services to function as expected, these ports must remain open through
any firewalls or switch access control lists that reside in between the SC Series sy